Industrial Pressure Transducer Transmitter , Hydraulic Pressure Transmitter
Material | Stainless Steel | Theory | Strain Gage Pressure Sensor |
---|---|---|---|
Pressure Range | 0-16Bar | Safety Overload | 150% |
Accuracy | 0.3% FS | Output Signal | 4-20mA/0.5-4.5V |
High Light | differential pressure transmitter,high temperature pressure transmitter |
Industrial Pressure Transducer Transmitter , Hydraulic Pressure Transmitter
Economic Pressure Transducer, Pressure Transmitter
Model: PT502
Introduction
PT502 series of pressure transmitter are mass production and low cost. Small size.
Application: compressor/Building Water Supply/Hydraulic Control/Air Conditioner, Medical Equipment etc
stainless steel material. the pressure sensing elements are selected from well-known international brands. Long terms stable, high precision
Parameter | Value |
Measure range | 0-3Bar.0-10Bar, 0-16Bar |
Overload Pressure | 1.5×RP(rated pressure) |
Broken Pressure | 3×RP(rated pressure) |
Accuracy | ±0.5,±1%F.S |
Stability | Typical ±0.5%F.S, Max ±1%F.S |
Operate Temperature | -40℃~100℃ |
Compensation Temperature | -10℃~80℃ |
Stock Temperature | -50℃~125℃ |
Wire | 2 Wires/3 wires |
Output Signal | 4~20mA/0.5-4.5v |
Power Supply | 12~30Vdc |
Load Resistance | (U-10)/0.02(Ω) |
Insulation | >100M Ω@50V |
Elec. Connect | DIN 43650C, DIN72585, Plug, Cable |
Elec. Connect | G1/4, NPT1/4, etc |
Response Time | 10ms |
Pressure Form | Gauge G, Absolute A |
Compliant | CE, Intrinsically safe E, Explosion-proof D |
EMC | EMI: EN50081-1/-2; EMS: EN50082-2 |